BỘ LƯU ĐIỆN OLS10000EXL
Mã sản phẩm: OLS10000EXL
- Công nghệ: ONLINE
- Công xuất : 10000VA/9000W
- Điện áp vào: 220 VAC
- Tần số nguồn vào: 45 – 65 Hz
- Điện áp ra: 208/220/230/240VAC
- Tần số nguồn ra: 50/60Hz ± 0.5%
- Thời gian chuyển: 0 ms
- Thời gian sạc : phụ thuộc vào pin bên ngoài
- Phụ kiện: User manual
- Thời gian back-up (full) : phụ thuộc vào pin bên ngoài
Liên hệ
Giao hàng toàn quốc
Thanh toán khi nhận hàng
Hoàn 100% tiền nếu hàng không đúng như web
Model | OLS10000EXL |
Capacity(VA/W) | 10000VA / 9000W |
Typology | Online (Double Conversion) |
Energy-Saving Technology | Yes, ECO Mode Efficiency > 96% |
Input | |
Input Type | Terminal Block |
Frequency Range | 45~65Hz |
Output | |
UPS Outlets (Numbers) | Terminal Block |
On Battery Output Voltage | Pure Sine Wave at 208, 220, 230, 240 Vac (Configurable) |
On Battery Output Voltage Distortion (@Nominal Battery Voltage) | < 2%(Linear Load), <5%(Non-Linear Load) |
On Battery Output Frequency | 50 Hz / 60 Hz (Auto-Sensing or Configurable) ± 0.5% |
Transfer Time (Typical) | 0ms |
Overload Protection | Line Mode: 10 minutes minimum,then transfer to bypass @105%<load≤125%; 1="" 10="" bypass="" load="" minimum="" minute="" second="" then="" to="" transfer="">150%; 1 second minimum then transfer to bypass@Load>170%; Battery Mode: 2 minutes minimum,then shutdown @105%<load≤125%; 1="" 30="" load="" minimum="" sec="" second="" shutdown="" then="">150% |
Short Circuit Protection | UPS Output Cut off Immediately or Circuit Breaker Protection |
Surge Protection and Filtering | |
Surge Protection | Yes |
DSL/Phone/Fax/Modem protection | No |
Physical | |
Dimensions(H x W x D)(mm) | 708 x 260 x 550 |
Weight(kg) | 28 |
Battery | |
Sealed Maintenance Free Lead Acid Battery | Depends on external batteries |
Extended Battery Module | BPSE240V47A |
Typical Recharge Time | Depends on external batteries |
Runtimes | |
Half load-Full load (mins) | Depends on external batteries |
Status Indication | |
Indicators | Power On, Line Mode, Battery Mode, Bypass Mode, ECO Mode,C/F Mode, Fault, Replace Battery |
Audible Alarms | Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery |
Communication | |
Power Management Software | PowerPanel® Business Edition |
Management | |
Self-Test | Yes |
Auto-Charge/Auto-Restart | Yes |
Auto-Overload Recovery | Yes |
Cold Start(DC Start) | Yes |
Connectivity Ports | (1) Serial Port (RS232), (1) USB Port, (1) EPO/ROO |
SNMP/HTTP Capable | Optional |
#All specifications are subject to change without notice.